Unigraf

Console: Changes to previous version————————— Added support for UCD-424. Added Firmware Update capability over USB. UCD-400, UCD-424: Added SSC support. Added support for HDCP 2.3 facsimile keys. UCD Console: Fixed bug in Pattern generator that caused all error messages to not show up. UCD Console: Fixed bug which caused incorrect H-Active size being sent out from DP TX after disabling DSC. UCD Console: Fixed bug which caused incorrect colorimetry to be used after disabling DSC on DP TX. UCD Console: Fixed issue which caused the Sink DUT DSC test CRC calculations to not properly follow the selected mode. UCD Console: Fixed HPD Event decoding in Event Logger. UCD Console: Removed „From“ and „F“ columns from Event Logger. UCD Console: Removed faulty „From“ column from Event Logger report generator.
UCD Device family software package updated. TSI software package updated. Fixed UCD-4xx device related shortcuts that were broken in previous bundle packages. Console: Changes to previous version————————— LLCTS: DSC: Sink DUT: Added max supported bpp check for different color modes. LLCTS: Sink DUT: Tests 5.2.1.1, 5.2.1.7, 5.2.1.10. Corrected handling of I2C NACK response LLCTS: Source DUT: Tests 4.2.1.1, 4.2.1.2 Implemented AUX reply timeout SCR LLCTS: Sink DUT: Test 5.3.1.8, 5.3.1.9. Corrected condition on Step 5. Fixed EQ status check for lanes 0 and 1 LLCTS: Sink DUT: Test 5.4.2: Set correct max bpc value based on Sink EDID LLCTS: Sink DUT: Test 5.4.4.4 Resolved Audio noise issue LLCTS: Source DUT: Test 4.4.4.5 Added check for video absence in case of audio only is checked LLCTS: Sink DUT: Tests
Console: Changes to previous version————————— LL CTS: Sink DUT: 5.4.4.6. Accurate configuration of channel number during test execution LL CTS: Sink DUT: 5.4.4.4. Set maximum sample rate that is supported by Sink DUT instead of default 44.1Khz UCD-400: DP TX: Prevent setting video mode that does not fit into maximum link bandwidth UCD-400: DP TX: FEC: Fixed ““Corrected parity 1 error“ error injection LLCTS DSC: Sink DUT: 5.6.2.12 – 5.6.2.14 no longer disable DSC when switch from incorrect to correct compressed pattern LLCTS: Sink DUT: Tests 5.4.1.1 – 5.4.2, 5.4.3.2 Verify TEST_CRC. LLCTS: Sink DUT: 5.4.1.1 – 5.4.3.2 add timing selection from EDID LLCTS DSC: Source DUT: 4.6.1.x Corrected TA pattern for non RGB mode. LLCTS DSC: Source DUT: 4.6.1.7 Fixed YCbCr420 DSC capability setting. LLCTS DSC: Source