Moxa ICF-1150-S-ST-T
ICF-1150-S-ST-T
ICF-1150 Series
Industrial RS-232/422/485 to single-mode fiber converter, ST connector, -40 to 85°C operating temperature
Serial Interface
No. of Ports
- 2
Serial Standards
- RS-232, RS-422, RS-485
Baudrate
- 50 bps to 921.6 kbps (supports non-standard baudrates)
Flow Control
- ADDC® (automatic data direction control) for RS-485
Connector
- 5-pin terminal block
DB9 male
Single-mode ST connector
- 5-pin terminal block
Optical Fiber
Optical Fiber
Low-Speed Fiber Module Multi-Mode Single-Mode Fiber Cable Requirements 50/125 µm, 800 MHz G.652 62.5/125 µm, 500 MHz Typical Distance 5 km 40 km Wavelength Typical (nm) 850 1310 TX Range (nm) 840 to 860 1290 to 1330 RX Range (nm) 800 to 900 1100 to 1650 Optical Power TX Range (dBm) 0 to -8 0 to -8 RX Range (dBm) 0 to -25 0 to -25 Link Budget (dB) 15 20 Dispersion Penalty (dB) 1 1 Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, ..., 0h) to the serial converter?s serial port.
Pull High/Low Resistor for RS-485
- 150 kilo-ohm, 10 kilo-ohm, 4.7 kilo-ohm, 3.3 kilo-ohm, 1 kilo-ohm, 909 ohm, 822 ohm, 770 ohm, 500 ohm, 485 ohm
RS-485 Data Direction Control
- ADDC® (automatic data direction control)
Terminator for RS-485
- N/A, 120 ohms, 120 kilo-ohms
Serial Signals
RS-232
- TxD, RxD, GND
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
- Data+, Data-, GND
Power Parameters
Input Current
- 264 mA @ 12 VDC
Input Voltage
- 12 to 48 VDC
No. of Power Inputs
- 1
Overload Current Protection
- Supported
Power Connector
- Terminal block
Power Consumption
- 264 mA @ 12 VDC
Physical Characteristics
Housing
- Metal
IP Rating
- IP30
Dimensions
- 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight
- 330 g (0.73 lb)
Installation
- DIN-rail mounting
Environmental Limits
Operating Temperature
- -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
EMC
- EN 55032/24
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 0.5 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
Environmental Testing
- IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
- IEC 60068-2-1
Safety
- EN 60950-1, IEC 60950-1
Vibration
- IEC 60068-2-6
MTBF
Time
- 792,085 hrs
Standards
- Telcordia (Bellcore), GB
Warranty
Warranty Period
- 5 years
Details