Moxa TN-5916-WV-T

Artikelnummer: TN-5916-WV-T

Herstellernummer: TN-5916-WV-T

Industrial NAT router with 16 10/100BaseT(X) ports, 4 10/100BaseT(X) ports with relay bypass function, WV power input, -40 to 75°C operating temperature

Kategorie: TN-5900 Series


Preis auf Anfrage
Muss bestellt werden. Ab Bestellung lieferbereit in 14 Tagen.


TN-5916-WV-T
TN-5900 Series

Industrial NAT router with 16 10/100BaseT(X) ports, 4 10/100BaseT(X) ports with relay bypass function, WV power input, -40 to 75°C operating temperature

Input/Output Interface
  • Alarm Contact Channels

    • 2 x relay output in one M12 A-coded 5-pin male connector with current carrying capacity of 1 A @ 30 VDC
Ethernet Interface
  • 10/100BaseT(X) Ports (M12 D-coded 4-pin female connector)

    • 12
  • 10/100BaseT(X) Ports (M12 D-coded 4-pin female connector with bypass relay)

    • 4
  • Standards

    • IEEE 802.1D-2004 for Spanning Tree Protocol
      IEEE 802.1p for Class of Service
      IEEE 802.1Q for VLAN Tagging
      IEEE 802.1w for Rapid Spanning Tree Protocol
      IEEE 802.3 for 10BaseT
      IEEE 802.3ad for Static Port Trunk
      IEEE 802.3u for 100BaseT(X)
      IEEE 802.3x for flow control
Ethernet Software Features
  • Configuration Options

    • Command Line Interface (CLI), Command Line Interface (CLI) through Serial/Telnet/SSH, Web Browser (HTTP/HTTPS), Windows Utility
  • Filter

    • 802.1Q, IGMP v1/v2, Static Multicast
  • Management

    • Back Pressure Flow Control, DHCP server, Flow control, HTTP, IPv4, LLDP, Port Mirror, QoS/CoS/ToS, RARP, SMTP, SNMP Inform, SNMP Trap, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Account Management
  • MIB

    • RFC1213
  • Redundancy Protocols

    • Link Aggregation, RSTP, Static Port Trunk, STP, Turbo Ring v2
  • Routing Redundancy

    • VRRP
  • Security

    • Broadcast storm protection Not supported in FW v1.2. , HTTPS/SSL, Local Account Accessibility, TACACS+ Not supported in FW v1.2. , Port Lock, SSH
  • Time Management

    • NTP Server/Client, SNTP
  • Unicast Routing

    • Static Route, RIPV1/V2
Switch Properties
  • IGMP Groups

    • 256
  • MAC Table Size

    • 8 K
  • Max. No. of VLANs

    • 16
  • VLAN ID Range

    • VID 1 to 4094
LED Interface
  • LED Indicators

    • STATE, PWR1, PWR2, FAULT, 10/100M
NAT
  • Features

    • 1-to-1, N-to-1, Port forwarding
Serial Interface
  • Console Port

    • M12 A-coded male connector
Power Parameters
  • Input Current

    • 0.85 A @ 24 VDC, 0.17 A @ 110 VDC
  • Input Voltage

    • 24/36/48/72/96/110 VDC, Redundant dual inputs, No. of power inputs: 2
  • Operating Voltage

    • 16.8 to 137.5 VDC
  • Overload Current Protection

    • Supported
  • Power Connector

    • M23 connector
  • Reverse Polarity Protection

    • Supported
Physical Characteristics
  • Housing

    • Metal
  • IP Rating

    • IP54
  • Dimensions

    • 250 x 175.8 x 116.3 mm (9.84 x 6.92 x 4.58 in)
  • Weight

    • 4,030 g (8.88 lb)
  • Installation

    • DIN-rail mounting (optional), Wall mounting
Environmental Limits
  • Operating Temperature

    • -40 to 75°C (-40 to 167°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 2000 m
Standards and Certifications
  • EMC

    • EN 55032/24
  • EMS

    • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
      IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
  • Freefall

    • IEC 60068-2-31
  • Radio Frequency

    • FCC
  • Railway

    • EN 50121-4, EN 50155, IEC 60571
  • Railway Fire Protection

    • EN 45545-2
  • Safety

    • IEC 60950-1, UL 61010-2-201
  • Shock

    • IEC 60068-2-27, IEC 61373, EN 50155
  • Vibration

    • IEC 60068-2-64, IEC 61373, EN 50155
Declaration
  • Green Product

    • RoHS, CRoHS, WEEE
MTBF
  • Time

    • 556,025 hrs
  • Standards

    • Telcordia SR332
Warranty
Kontaktdaten
Frage zum Produkt